Contact Breaker

A contact breaker, commonly called ignition points, switches current through the ignition-coil primary winding on many classic petrol engines. A cam inside the distributor opens the contacts at the correct crank angle. The collapsing coil field then creates high voltage for the spark plug, while a condenser suppresses arcing and helps the magnetic field collapse quickly.

Select points by distributor manufacturer and exact distributor number, not vehicle model alone. Engines of the same year can use different distributors, pivot layouts, heel profiles, terminals and spring tensions. Match the condenser specification, low-tension lead and any insulating washers. A visually similar set can ground permanently or alter dwell.

Contact gap is only an initial setting; dwell angle measures how long the points remain closed during each distributor cycle. Too little dwell limits coil saturation, while too much can overheat the coil and points. Heel wear gradually closes the gap and retards ignition timing, so dwell must be set before final timing. Distributor shaft wear can make the gap vary between cam lobes.

Hard starting, misfire under load, weak spark, burnt contacts or unstable timing are not proof that the points alone are faulty. Check battery voltage, coil resistance and polarity, ballast wiring, condenser, distributor earth, cap, rotor, advance mechanisms, leads, plugs and fuel condition. A deeply pitted contact pair often points to an incorrect or failing condenser. Inspect the distributor cap for tracking and moisture under bright, safe lighting.

Disconnect the battery before fitting. Keep oil and fingerprints off the faces, preserve every insulator, lubricate the cam sparingly with the specified grease and route the flexible lead clear of moving parts. Set gap/dwell, then ignition timing using vehicle data and confirm mechanical and vacuum advance. Recheck dwell after tightening because the plate can shift slightly. Stop if wiring overheats or the coil becomes abnormally hot. Vehicle-specific contact-breaker sets are listed below.

Your Current Vehicle

Or

Select Your Vehicle

Contact Breaker for Popular Car Brands

Vehicle Models and Options for Contact Breaker

Alfa Romeo Car Parts

ALFA ROMEO GIULIA

3 matching products

austin car parts

AUSTIN MINI

3 matching products

ford car parts

FORD CORTINA

3 matching products

ford car parts

FORD ESCORT

3 matching products

ford car parts

FORD ZEPHYR

3 matching products

ford car parts

FORD ZODIAC

3 matching products

land-rover car parts

LAND ROVER 110

3 matching products

Morris Car Parts

MORRIS MINI

3 matching products

Rover Car Parts

ROVER 2000-3500

3 matching products

Volvo Car Parts

VOLVO 140

3 matching products

Alfa Romeo Car Parts

ALFA ROMEO 1750-2000

2 matching products

Alfa Romeo Car Parts

ALFA ROMEO GIULIA GT

2 matching products

Alfa Romeo Car Parts

ALFA ROMEO GT

2 matching products

Alfa Romeo Car Parts

ALFA ROMEO SPIDER

2 matching products

austin car parts

AUSTIN ALLEGRO

2 matching products

austin car parts

AUSTIN MAXI

2 matching products

austin car parts

AUSTIN PRINCESS 2

2 matching products

BMW Car Parts

BMW 1502-2002

2 matching products

Fiat Car Parts

FIAT 1

2 matching products

ford car parts

FORD CAPRI

2 matching products

ford car parts

FORD CORSAIR

2 matching products

ford car parts

FORD TRANSIT

2 matching products

HILLMAN Car Parts

HILLMAN AVENGER

2 matching products

INNOCENTI Car Parts

INNOCENTI MINI

2 matching products

Filter products

The highest price is £20.37
£
£

2 Products

Points control energy stored in the ignition coil

With the contacts closed, battery current builds a magnetic field in the coil primary winding. At the firing point, the distributor cam opens them. The rapid field collapse induces high voltage in the secondary winding, which reaches the appropriate plug through the rotor and cap.

The system is simple but dynamic. Coil current, contact opening speed, dwell, condenser value and distributor accuracy all influence spark energy and timing.

Components in a conventional ignition system

ComponentFunctionTypical faultEffect
Contact setSwitches primary current.Burning, contamination, heel or pivot wear.Weak/erratic spark and timing drift.
CondenserControls arcing and speeds field collapse.Open, shorted or wrong capacitance.Rapid point damage or no spark.
Ignition coilTransforms stored magnetic energy to high voltage.Winding, insulation or heat failure.Weak/no spark, often hot.
Distributor camOpens points once per cylinder event.Wear, corrosion or poor lubrication.Unequal dwell and heel wear.
Shaft/bushesKeep cam concentric and timed.Radial play.Timing scatter between cylinders.
Advance mechanismsAlter timing with speed and load.Seized weights or split vacuum unit.Poor response, economy or knock.

Dwell angle is more informative than static gap

Set dwell before setting timing

Dwell is the distributor rotation during which the points remain closed. Increasing contact gap reduces dwell; decreasing gap increases it. A feeler gauge establishes a workable starting point with the rubbing heel on a cam peak, but a dwell meter measures the system while operating.

Changing dwell changes the instant the points open, so it changes ignition timing. Complete gap or dwell adjustment first, then set timing.

Why the condenser matters

When the contacts begin to open, the coil primary tries to maintain current and would arc strongly across the small gap. The condenser temporarily accepts charge, reducing arcing and forming an oscillating circuit with the coil. Its capacitance must suit the system.

A shorted condenser can prevent primary interruption and produce no spark. An open or poorly earthed condenser allows severe arcing. Metal transfer from one contact face to the other can provide clues, but correct diagnosis includes wiring and coil checks.

Identify the distributor, not just the car

IdentificationVariationMismatch risk
Distributor numberManufacturer code and suffix.Wrong pivot, heel or base plate fit.
RotationClockwise or anticlockwise distributor.Heel and spring geometry incorrect.
Terminal styleScrew, spade, post or flying lead.Short circuit or insecure connection.
Insulation stackWashers and bushes isolate low-tension terminal.Permanent earth and no spark.
Coil systemBallasted or full battery voltage.Excess current or weak spark.
Cylinder count/camNumber of lobes changes dwell specification.Incorrect universal setting.
CondenserCapacitance, lead and mounting differ.Point burning and unreliable ignition.

Ballast-resisted and unballasted coils

Some systems use a lower-resistance coil with a series ballast during normal running, then bypass it for a stronger spark while cranking. Others supply a coil designed for full system voltage. Mixing them can overheat points and coil or reduce spark energy.

Measure primary resistance with suitable equipment and compare the complete circuit with wiring data. Coil labels are useful but not conclusive after decades of replacement and rewiring.

Contact condition provides diagnostic evidence

AppearancePossible reasonResponse
Light grey, even facesNormal service deposition.Check dwell and wear.
Deep pit and peakCondenser value/earth issue or high current.Test condenser, coil and supply.
Blue/burnt springExcess current or poor contact seating.Verify ballast and alignment.
Oily glazed facesOver-lubrication or vapour contamination.Correct source and renew points.
Gap repeatedly closesDry cam, soft heel, loose screw or shaft issue.Inspect cam, hardware and lubrication.
Unequal opening by lobeWorn shaft, cam or base plate.Measure distributor run-out/play.

Symptoms and diagnostic priorities

A failing low-tension circuit can cause cranking without firing, intermittent cut-out, misfire at high rpm or weak spark under cylinder pressure. Heat may worsen a coil or condenser fault. Fuel starvation and carburettor problems can feel similar, so establish whether spark disappears when the symptom occurs.

Use an appropriate spark tester rather than holding a lead. Verify battery cranking voltage, coil positive feed, primary switching and a sound distributor earth. High-voltage ignition can cause injury and damage electronic test equipment.

Distributor shaft and base-plate checks

Radial shaft movement changes the point gap as the cam turns, producing timing scatter that fresh points cannot cure. Check all lobes and compare dwell stability. Axial movement can also shift timing on helical-drive distributors.

Vacuum advance rotates a movable base plate. Its braided earth lead must remain flexible and conductive throughout travel. A fractured lead may fail only when manifold vacuum moves the plate.

Safe removal and installation

StageCorrect methodError prevented
IsolateSwitch off and disconnect battery as specified.Coil overheating and accidental short.
RecordPhotograph lead, washers and condenser routing.Misassembled terminal insulation.
Inspect camCheck lobes, shaft play and surface.Sacrificing new heel to a rough cam.
Fit pointsSeat pivot and base flat; tighten securely.Moving adjustment and misalignment.
Route leadAllow base-plate travel without touching cam.Intermittent short or broken conductor.
LubricateApply only specified tiny amount to cam.Heel wear without contact contamination.
Set and verifyStatic gap, running dwell, then timing.Incorrect coil charge and firing point.

The insulating washers are functional parts

The coil-negative conductor and moving contact must be insulated from the distributor body until the points close. A shoulder bush and washers often isolate the terminal post. Assemble one washer on the wrong side and the circuit may remain earthed continuously.

With the points open and ignition off, continuity testing can confirm isolation. Rotate or move the vacuum plate while testing to expose a chafed flexible lead.

Initial gap setting

Rotate the engine in its normal direction until the rubbing heel rests at the top of a cam lobe. Use a clean feeler gauge of the specified thickness and adjust until it slides with the stated light drag. Tighten the screw while preventing the plate from moving, then recheck.

Do not file a new contact set. On used points, a feeler gauge spanning a pit and peak can misrepresent effective separation, which is another reason to check dwell.

Running dwell and timing

Connect instruments with correct polarity and away from belts and fans. Compare dwell at idle and raised speed; large variation indicates mechanical instability. Once dwell is correct, set base timing with vacuum connections handled exactly as service data specifies.

Confirm centrifugal advance progresses with rpm and returns freely. Test vacuum advance with a controlled vacuum source and verify the diaphragm holds. Excess advance can cause knock and engine damage; retarded timing creates heat and poor response.

Starting current and coil temperature

Leaving the ignition switched on with closed points holds continuous coil current. The coil and contacts can overheat, and some coils may leak or rupture. Do not leave the system energised during adjustment.

After commissioning, check that the coil is appropriate and not becoming abnormally hot. Measure voltage on both sides of any ballast during running and cranking rather than bypassing it by assumption.

Electronic conversion considerations

A contactless trigger can reduce routine dwell wear, but it must match distributor, coil resistance, supply voltage and polarity. It does not repair shaft play, seized advance or a damaged cap. Retain clear wiring records and any original components needed for diagnosis.

Some electronic modules need full supply while the coil remains ballasted. Follow the conversion instructions exactly; connecting both to whichever terminal is convenient can make the module unreliable.

Maintenance and roadside diagnosis

At specified service intervals, inspect gap/dwell, faces, heel, distributor cam, cap, rotor and advance. A small clean spare set and correct tools can be useful on an older vehicle, but roadside work must be away from traffic with the ignition isolated.

Do not repeatedly sand burnt points without correcting the condenser or current fault. Abrasive debris left between contacts prevents reliable low-resistance closure.

MOT, emissions and roadworthiness

Ignition misfire can raise exhaust emissions, overheat a catalytic converter where fitted and make an engine stall in traffic. Secure wiring and correct timing are therefore more than refinement issues. A vehicle must meet the applicable emissions and roadworthiness requirements for its age and class.

If fuel vapour is present, stop before creating sparks. Repair leaks and ventilate safely before ignition testing.

Practical contact-breaker FAQs

Q: Are contact breakers the same as points?
A: Yes. Both terms describe the mechanical primary-current switch.

Q: Should gap or timing be set first?
A: Set gap and dwell first, because they change the firing point.

Q: Why do new points need a condenser check?
A: A faulty or mismatched condenser can rapidly burn the new contacts.

Q: Can points be selected by registration alone?
A: Distributor number is safer because several units may fit one model.

Q: What closes the points?
A: Their spring closes them after each distributor-cam lobe passes.

Q: Why does the gap become smaller?
A: Rubbing-heel wear, loose adjustment or cam/shaft faults can close it.

Q: Can oil be put on the contacts?
A: No. Only a tiny specified lubricant belongs on the cam/heel interface.

Q: What causes timing scatter?
A: Shaft play, worn cam, loose base plate or unstable point opening.

Q: Does a spark in open air prove ignition is healthy?
A: No. Cylinder pressure demands more voltage, so weak systems can still misfire.

Q: Can a ballast resistor be removed?
A: Not unless the complete coil system is correctly redesigned.

Q: Why does the coil overheat with ignition left on?
A: Closed points allow continuous primary current without normal switching.

Q: Will electronic ignition cure distributor wear?
A: No. Mechanical play and advance faults remain.

Q: Is high-voltage ignition testing dangerous?
A: Yes. Use an insulated purpose-designed tester and safe procedures.